search
find a service centre
Macnaught Pty Ltd » flow meters » m-series™ positive displacement flow meters


Click to enlarge Click to enlarge

M05 - 1/8" pulse meters

The M05 is a small capacity meter in the M-SERIES™ range and is differentiated by its flow rate capabilities. It has the ability to handle a wide range of fluid viscosities with exceptional levels of repeatability and durability.

Features

  • Very compact size.
  • Low flow capability with high resolution output.
  • Meter accuracy is verified by a factory calibration check after which an individual metrology report is issued.
  • Solid state Hall Effect Sensor/Reed Combination.
  • Low pressure drop allows for economical pump selection or gravity flow applications.
  • Meter design minimises the number of wearable and replaceable parts and extends product life.
  • Has IP54/NEMA13 protection.
  • Flexibility of installation options (e.g. can be mounted horizontally or vertically; no flow conditioning required).

Specification:

Model M05SSP-X M05ASP-X
Meter Type Pulse Pulse
Meter Body Material 316 Stainless Steel Aluminium / PPS
Wetted Components:
Rotor Material
Shafts
O'ring
316 Stainless Steel / Ceramic
316 Stainless Steel
FKM
316 Stainless Steel / Ceramic
316 Stainless Steel
FKM
Flow Rate Ranges
(Litres Per Hour/US Gallons Per Hour)
Above 5 cPs
Below 5 cPs
0.5 To 50 / 0.13 To 13.2
2 To 50 / 0.53 To 13.2 (Excluding Water)
0.5 To 50 / 0.13 To 13.2
2 To 50 / 0.53 To 13.2
Accuracy- Within (Of Reading) ±1% ±1%
Repeatability 0.03% 0.03%
Maximum Viscosity 1000 Centipoise 1000 Centipoise
Maximum Operating Pressure 1000kpa/ 150psi/ 10bar “I” 5500kpa/ 800psi/ 55bar 500kpa/ 75psi/ 5bar
Pulser Type Dual Hall Effect Sensor/Reed Switch Dual Hall Effect Sensor/Reed Switch
Pulses Per Litre/Us Gallon 1547 / 5855.4 1547 / 5855.4
Model Dimensions
Meter Body
Port Face To Face
50x50mm / 1.97”X1.97”
67mm / 2.64”
50x50mm / 1.97”X1.97”
60mm / 2.36”
Weight 600g / 21.2oz 310g / 11oz
Max. Operating Temperature 120°C / 248°F 80°C / 176°F
Recommended Mesh Strainer 200 Mesh 200 Mesh

X = Port SizeTo order flowmeter you must replace ‘X’ with the relevant number. Meter mounted options = MR100 LCD and or MR150LA (4-20mA - module) or combination of both.


Port Size

Port Size: Calibrated In: Electrical Connection:
1 = 1/8” BSP (F) ports Litres 1m/39” pulser fly lead (5 core cable)
2 = 1/8” NPT (F) ports US gallons 1m/39” pulser fly lead (5 core cable)

PPS = Polyphenylene Sulfide Resins
Note: Water usage is limited due to poor lubricating quality of the fluid limiting accuracy and bottom end stable operation.


Options and accessories

M05 - 1/8” Pulse Meters M05SSP-X M05ASP-X
FKM O-Ring
FFPM Elastomer Ο Ο
EPDM O-Ring Ο Ο
High Temp Rotors - -
High Viscosity Rotors - -
Hall Effect Sensor
Reed Switch
Solvent Kit - -
PPS Rotors With Hastalloy C Shafts - -
Remote Mounted LC Display + +
4-20ma Module (Remote) + +
Meter Mounted LC Display + +
Meter Mounted 4-20mA Module + +

• Standard   Ο Optional   - Not Available   + Accessory